C-Mic Auto Test System Type BK9010B
The Fully Automatic C-Mic Tester:
Based on the BK3010V2 C-Mic Tester, the
BK9010B is our fastest C-mic test system. Fully automatic, the
BK9010B loads the mics in place and after testing, it sorts passing
microphones into 8 quality classes, and failing microphones
according to the reason they failed. Each mic is put into
its appropriate bin. As testing progresses, you can view
the data graphically in real time or save it to be viewed
or analyzed later.
This machine is also avaliable as the BK9010E Fully Automatic MEMS Mic Tester. If you'd like to know more about our BK9010 fully automatic testers, email me here.
This machine is also avaliable as the BK9010E Fully Automatic MEMS Mic Tester. If you'd like to know more about our BK9010 fully automatic testers, email me here.
NEXT
Specifications:
General:
No of Channels: 4Ch x 2
Measurement Time:
With auto pin select function: >1sec/4Ch (added
depending on microphone)
Without auto pin select function: >0.5sec/4Ch (added
depending on microphone)
Max. Channels: 4Ch x 2
C-Microphone Interface:
C-Mic. Power Voltage: 1~5V/0.1V step
Resistor: 680, 1k, 1.5k, 2.2kΩ 2%
Current Measurement Range: 900µÅ
Automatic Pin Sign Detector: Max. 4Pin
C-Mic. Cable Length: 2m
Acoustic Measurement
Measurement Level Range: -20 to -70dBV/Pa
Measurement Frequency: 200Hz, 1kHz, 5kHz, 8kHz (Option),
(Other frequencies: Option)
Measurement Accuracy:
Sensitivity:
±0.1dB at -10dB to –70dBV/Pa
±0.2dB at -70dB to –90dBV/Pa
Low Band:
±0.1dB at -10dB to –70dBV/Pa
±0.2dB at -70dB to –90dBV/Pa
High Band:
±0.1dB at -10dB to –70dBV/Pa
±0.2dB at -70dB to –90dBV/Pa
Test Mode:
Average Mode: Normal
Auto Accuracy Control: No
Calibration
Sample Calibration: Auto Calibration using Ref. D-Mic.
and samples.
Sound Pressure Calibration: Auto Calibration using B&K
microphone (Option)
NEXT
Signal Generator:
Test Frequency Accuracy:
Sens. (1kHz): ±0.01%
Low (200Hz): ±0.01%
High (5kHz, Option: 8kHz): ±0.01%
Signal Level Stability at –30dBV/Pa: ±0.05% (24Hour)
Acoustical Output: 94dBspl ±5 dB using Optional Test Coupler
PLC Interface:
Test Result Output: BCD Code Output via Open Collector Output
Test End Signal: Yes
Test Profile Setup
Sens. Rank: 7 Step Low, Upper (Grades 1-7, OVR/SENS)
FRF Rank: Low Band and High Band vs 1kHz
Current Limit: Open, Short, IDO
Display
Display: Count,
Absolute, Grade, Sens, Low, High
Relative (to Sens): Low, High
Test Result
Test Result Output
OK Grades: Grade1, Grade2, Grade3, Grade4, Grade5,
Grade 6, Grade7
NG Grades: SEN, OVR, FRQ, IDO, OPS